• LISTED Installation Manual VERSION 2.20 IM728-738 9. • IM728-738 Requirements and guidelines for U.L. INSTALLATIONS UL listed in accordance with standard UL1023 (Household Burglar - Alarm System Units), standard UL985 (Household Fire Warning Units) and UL1635 (Digital Alarm Communicator System Units). UL has only evaluated the 718, 728L, 728, 728 EXPRESS, 738, 738 EXPRESS and 748 for compatibility with the Ademco model 685, FBI model CP220FB, SUR-GUARD SG-MLR2-D6 and Silent Knight model 9000. • IM728 -738 TABLE OF CONTENTS REQUIREMENTS/GUIDELINES FOR UL, ULC AND AUSTELINSTALLATIONS INTRODUCTION.ABOUT THIS MANUAL.
• IM728 -738 TABLE OF CONTENTS (continued) Telephone and Account Numbers.Computer telephone number.Central station telephone numbers. • IM728 -738 TABLE OF CONTENTS (continued) Delay 2.Bypass-enabled. • We hope that the important features of the Esprit 728 and Esprit 738, which include a 120-event, PC- uploadable event buffer and high-speed pre-programmed communicator formats, will simplify your task of supplying quality security service to your customers. • IM728-738 Programmable Outputs Almost any control panel status situation may be used to activate the Esprit’s programmable outputs. Once a panel status mode is selected for a PGM to follow, the polarity and duration of the output may also be programmed. 18 supplementary programmable outputs are available with the SRI18 module, which connects to the panel’s serial output.
Sekonic Manual em portugu s installer guide guia de programaci n central alarme paradox 728/. Qual femininos massagem gretchen ouvir manual brasilia trade slide.
• IM728-738 Digital Communicator: Compatible with most worldwide telecommunication standards. Reporting formats: Pulse: Ademco slow (10BPS), Silent Knight fast, Sescoa (20 BPS) Radionics, Radionics with parity (40 BPS), 1400Hz - 1800Hz (10 BPS) DTMF: Contact ID, Ademco Express, “No handshake” DTMF format. (Pager) True Dial tone detection and telephone line monitoring. • IM728-738 EARTH GROUND The earth terminal should be connected to the cabinet and grounding rod as per local electrical codes. Use a 16.5VAC (50-60 Hz) transformer with a minimum 40VA rat- ing to provide sufficient AC power.
Download Amoi Zte 3g Tools Free. Do not utilize any switch-con- trolled outlets to power the transformer. Driver Samsung 732n Plus on this page. • IM728-738 KEYPAD CONNECTIONS Panel/keypad connection: The four keypad connections labeled 'red', 'black', 'green' and 'yellow' should be connected to the corresponding colour terminals on the control panel PC board.
Keypad zone connection: The two connections labeled 'zone' and 'com' are used to connect a zone to the keypad. • IM728-738 SINGLE ZONE connection with a 1K EOL resistor (N.C. Contacts) address 208, key [ ] = 'off' (default) key [10] = 'off ' (default) key [11] = 'off ' (default) SINGLE ZONE connection with a 1K EOL resistor, tamper recognition (N.C. • IM728-738 Exception: When the zone definition is '24 hour', the tamper definition follows the audible/silent alarm arm definition of the '24 hour' zone. Tamper recognition addresses: Tamper report and restoration codes should be programmed at addresses 191 and 180.
FIRE CIRCUIT The fire zone (enabled by defining zone 3 as '24 hour') should always be connected with a 1K EOL resistor (PN201100200-PRT on UL systems). • IM728-738 Panel Programming Methods To conduct panel programming, use the keypad or initiate communication with Espload (see page 11). Use of Espload is highly recommended, as it greatly reduces the potential for data entry errors during programming. For Keypad Programming instruction, refer to 'Programming Guide'. Battery Hook-Up (required on UL/ULC installations) Use a 12VDC 7AH rechargeable acid/lead or gel cell battery. • IM728-738 Panel Answer Options: (Address 000) DIRECT ADDRESS The first digit entered disables the “Answering Machine Override” (key [2 ] or key [1]), or determines the period of time between first and second call. The second digit entered determines the number of rings required before the panel will answer.
If ] is entered, the panel will not answer. • IM728-738 Telephone and Account Numbers Three telephone numbers can be programmed: a PC telephone number and two central station numbers. Each number can contain a maximum of 16 digits. Special instructions can be entered in the telephone numbers using the following keys: [10] = the number '0'. Finale 2010b V15.2.r1 Update Crack Only.
• IM728-738 Zone alarm codes: (Addresses 120-143) SECTION 15 - 20 Alarm report codes programmed will be sent to the monitoring station, identifying the zones that are gen- erating alarms. Zone restore codes: (Addresses 144-167) SECTION 21 - 26 Zone restoration codes programmed will be sent to the monitoring station, identifying zones returning to normal status after alarms. • IM728-738 Ademco contact ID (selected codes reported) (key [9]) Select certain report codes to be reported by entering any value other than [2 ] at the required addresses. The preprogrammed Contact ID report code for that event will then be reported.